NODE 02 / HYPASS TECHNICAL ARCHIVERECORDS FILED BY NUMBER
HYPASSTECHNICAL ARCHIVE
HP-REC

AIR CONDITIONING HOSE

FILED / 2026-07-16 16:37:47PROFESSIONAL HOSENODE 02

01.jpg

Main Testing Equipment and Instruments: Pulse testing machine, electronic tensile testing machine, burst testing bench, vacuum testing bench, flatbed vulcanization meter, high-temperature aging oven, high-low temperature alternating chamber, ozone aging chamber, rotorless rheometer, Mooney viscometer, projector, laboratory miniature internal mixer, and open mixing mill.

03.jpg

04.jpg

05.jpg

06.jpg

07.jpg

08.jpg



TEST ITEM

STANDARD

TEST CONDITION

BEB SERIES

BEH SERIES

BCB SERIES

BCH SERIES
渗透性实验
PERMEATION TEST
最大 9.7kg/m²/yr
MAX 9.7kg/m²/yr
80℃ X28day<3.0<3.0<1.6<1.6
老化试验
AGING TEST
无裂纹
NO CRACKS
135℃/168h合格
QUALIFIED
合格
QUALIFIED
合格
QUALIFIED
合格
QUALIFIED
低温试验
COLD TEST
无裂纹
NO CRACKS
-40℃/24h合格合格合格合格
真空塌瘪
VACUUM FLATTENING
最大 20%
MAX 20%
10mm Hg2.00%0.40%2.00%0.40%
长度变化
LENGTH CHANGE
-4% — +2%压力 2.4and 2.7MPa
PRESSURE 2.4and 2.7MPa
0.41-0.3-0.8
爆破强度
BURSTING STRENGTH
12.0MPa 13.7MPa速率 69MPa/min
RATE 69MPa/min
>18>19>20>20
定压试验
PROOF TEST
无异常
NO ABNORMALITIES
50%爆破强度30S~5min无泄漏
NO LEAKS
无泄漏
NO LEAKS
无泄漏
NO LEAKS
无泄漏
NO LEAKS
抽取试验
EXTRACTION TEST
最大 118g/m²
MAX 118g/m²
R-134a 70℃/24hrs30324852
臭氧试验
OZONE TEST
无裂纹
NO CRACKS
50pphm 40℃/70hrs合格
QUALIFIED
合格
QUALIFIED
合格
QUALIFIED
合格
QUALIFIED
清洁度试验
CLEANNESS TEST
最大 270mg/m²
MAX 270mg/m²

20202226
水分渗透性
MOISTURE INGRESSION
最大0.25-0.70g/in2/gr
MAX0.25-0.70g/in2/gr
湿度85%
HUMIDITY85%
0.320.350.220.2
脉冲实验
PULSE EXPERIMENTS
无损坏
NO DAMAGE
150000次压力循环
150000 TIMES PRESSURE CYCLE
无损坏
NO DAMAGE
无损坏
NO DAMAGE
无损坏
NO DAMAGE
无损坏
NO DAMAGE